MSP-Controller:
-
Simple installation and configuration
-
Fully dedicated and tuned for use with “WindRotor” wind
turbine
-
State-of-the-art Digital Signal processor system
-
Easy connection to grid, batteries, wind turbine,
photovoltaic system, Genset
-
(requires always the use of batteries 200Am min)
-
Integrated anti-islanding fixtures (Enel – VDE0126 – UL
1741)
-
Over-voltage protection / DC- AC Galvanic isolation

|
|
wind turbine input
(three-phase generator permanent–magnet synchronous) |
MPPT range 45/35Vdc hysteretic to 400Vdc
max frequency 120Hz
power
max. 5000W |
|
Photovoltaic input
Recommended PV array configurations |
Voltage max: Series of 144 Silicon cells (95V)
Current, max: 20A
Parallel of strings up to the max current. Each string
can be 4 panels 12V, or 2 panels 24V |
|
Genset input |
The Genset can be used to feed the load and to charge
the battery.
To feed the load the Genset must be connected to the
GENSET input terminal.
To charge the battery the Genset must be connected to
the TOUT input terminals by means of an isolation
transformer
Max Genset current to feed the load: 20A
Max Genset current to charge the battery: 12A |
|
Battery
|
nominal Voltage 48Vdc
Voltage range 42-60Vdc
Max. current 110Am |
|
Inverter |
230Vac single phase or 115Vac split phase
Power, nominal 4500W
Power, overload (<1min) 5500W |
|
Protections |
All regulations are consistent with applicable standards
(UL 1741, VDE 0126, etc.). In particular:
Over current and short circuits
Over voltage, Under voltage, Frequency
Over temperature
Anti-islanding
Ground Fault Interrupt (GFI) |
|